Описание

  • Control panel
  • Emergency stop according to ISO 13850
  • 6 pushbuttons illuminated
  • 6 selector switches, 3-stage, illuminated
  • Including adhesive labels
  • Push-pull plug
  • Including terminal plug for Stacklight (M12, 8-pin)
  • Including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
Profinet connection Connection via push-pull plugs according to IEC 61076-3-117 Profinet RT switch Point-to-point topology network structure due to integrated RT switch. Dimension drawing MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawing Technical dataApprovals Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 2,7 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP54
Resilience to vibration In accordance with EN 60947-5-3
Installation orientation Any
Reaction time
Emergency stop / machine stop max.250 ms Switch-off time
Enabling switch max.250 ms Switch-off time
Switching frequency 0,25 Hz
Connection
Push-pull power
Push-pull power
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45
Push-pull RJ45
Plug connector RC12
Plug connector M12
Electrical connection ratings
Current consumption max.500 mA
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0,5 kV
Maximum feed-in current in the connection block
X1, X2 max.4000 mA
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Safety class III
Power supply X1
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Fusing
external min.1 A Slow blow
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Interface, bus
Data interface
Data protocol
Bus protocol Profinet (IEC 61158 type 10)
Safety protocol Profisafe (IEC 61784-3-3)
Controls and indicators
Belegungsschema C1
Belegungsschema B1
Position 10
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe white
Schaltelement 1NO
Position 11
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe white
Schaltelement 1NO
Position 12
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe white
Schaltelement 1NO
Position 13
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe white
Schaltelement 1NO
Position 14
Ausfuhrung Selector switch, illuminated
Einlegeschild
Extras
Farbe
Schaltelement 2S
Position 15
Ausfuhrung Selector switch, illuminated
Einlegeschild
Extras
Farbe
Schaltelement 2S
Position 16
Ausfuhrung Selector switch, illuminated
Einlegeschild
Extras
Farbe
Schaltelement 2S
Position 17
Ausfuhrung Selector switch, illuminated
Einlegeschild
Extras
Farbe
Schaltelement 2S
Position 90
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe white
Schaltelement 1NO
Position 91
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe white
Schaltelement 1NO
Position 93
Ausfuhrung Emergency stop
Einlegeschild
Extras
Farbe
Schaltelement 2 pos. driven NC
Position 94
Ausfuhrung Selector switch, illuminated
Einlegeschild
Extras
Farbe
Schaltelement 2S
Position 95
Ausfuhrung Selector switch, illuminated
Einlegeschild
Extras
Farbe
Schaltelement 2S
Other
Product version number V3.30.10
Slide-in label
12 pcs. without marking
Acknowledge symbol 1
Acknowledge symbol 2
Reliability values according to EN ISO 13849-1
Emergency stop
B10D
Emergency stop 0.1 x 106
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Enabling switch
B10D
Enabling switch According to manufacturer’s specifications
Enabling switch evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Performance Level PL e
Category 4
Safety Integrity Level SIL 3 (EN 62061:2005)
Diagnostic Coverage (DC) 99
Mission time 20
''